Recent content by rainylsh

  1. R

    database symix was not be connected

    I've found the way, fill the follow in the beginning of the source: def new shared var call-num as int. {menu/cachedef.i "new"} run lib/db-alias.p.
  2. R

    How to print Bar Code using Syteline 6

    1.HP 3000 series or up type driver with barcode mode can print bar code. 2.the third support, like excel using bar code controler
  3. R

    database symix was not be connected

    I study to run queue using batch cmd. but when i try to run the batch cmd , it shows some error msg. like:database symix was not be connected in batch\rpt.p (1006), I also try to run r-code file :batch\rpt.r, but still faild, can you tell me why? and help me to solve? my database name is sl, how...
  4. R

    ** "file" was not found. (293)

    Maybe your network works not good, or client was off-line.
  5. R

    How to print Bar Code using Syteline 6

    I want print bar code into transfer form, Can you tell me how to print a character to be bar code? what will i prepare? a special printer? it's better if you can give me a example. thanks .
  6. R

    Set Progress DB .PF file

    Thank you Very Much. I has not know what effect some parameters run. I'll study hard to understand. I'm doing some change by your reply. look forward to good news.
  7. R

    Set Progress DB .PF file

    this is my .st file. as i know, the block size is 8k it's enterprise,Progress version is 9.1D. According to Progress help file, I set the -B = (8 * users) 2 = (8 * 40) 2 = (8 * 35)2 = 78400 ~ 80000 # b r:\dtsd.b1 # d "Schema Area":6,64 r:\dtsd.d1 f 512000 d "Schema Area":6,64 r:\dtsd.d2 f...
  8. R

    Set Progress DB .PF file

    Dear guys: help to look the following parameter file: server 2.4G*2, Mem:4G Where we can change to improve the performance? /*********** -L 81920 -TB 16 -TM 15 -inp 5000 -rand 2 -n 35 # # MAIN,dtsd -db r:\dtsd -B 80000 -H dtgdsdsvgc03 -S dtsd -N tcp ***********/
  9. R

    Can Syteline6 use progress 10?

    Thanks. You give me more confidence
  10. R

    Can Syteline6 use progress 10?

    Yes, I don't afraid, but I have not a method to make sure whether it is ok.
  11. R

    Can Syteline6 use progress 10?

    What you said is realy safety. even has danger, we can restore it. But what i think is if it has been upgraded, how to make sure all of the progress running ok? Need I spend time as more as possible on testing all of the progress files?
  12. R

    Can Syteline6 use progress 10?

    We've source. but The thing that all will be compiled maybe make some troubles. I can not run the risk.
  13. R

    Can Syteline6 use progress 10?

    you mean? all of the .p .w files need be compiled? if then, i think no one want to update progress version.
  14. R

    Can Syteline6 use progress 10?

    Dear all: We are now use 9.1C, I don't know whether syteline 6 can use 10. Any one can tell me?
  15. R

    How to unlock a table which was lucked

    Sorry, I don't understand clearly. can you tell me How to use Promon.
Top